Ehrlichia Leishmania Anaplasma Heartworm Combo Test

Product Details
Customization: Available
Type: Detection Card
Used for: Ehr Ana Lsh Chw Test Test
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
147802.18 USD
Type of Ownership
Limited Company
  • Ehrlichia Leishmania Anaplasma Heartworm Combo Test
  • Ehrlichia Leishmania Anaplasma Heartworm Combo Test
  • Ehrlichia Leishmania Anaplasma Heartworm Combo Test
  • Ehrlichia Leishmania Anaplasma Heartworm Combo Test
  • Ehrlichia Leishmania Anaplasma Heartworm Combo Test
  • Ehrlichia Leishmania Anaplasma Heartworm Combo Test
Find Similar Products

Basic Info.

Model NO.
VD084
Sensitivity
>97.50%
Specificity
>97.50%
Accuracy
>98.00%
Specimen
Serum, Plasma and Whole Blood
Assay Time
5-10 Minutes
Sample
Supply
Delivery Time
3~5days After Get Payment
Storage Temperature
2-30 Degree
Shelf Life
18 Months
Payment
T/T, Western Union, Paypal
Customized
Accpet
Box Size
15cm*10cm*8cm
Packing
80 Boxs/Carton
Carton Size
68cm*44cm*44cm
Transport Package
Carton
Specification
10 Tests per box
Trademark
VET Diagnostix
Origin
China
HS Code
3822001000
Production Capacity
1 Million/ Week

Product Description

Canivet EHR-LSH-ANA-CHW Combo Test


The Canivet EHR-LSH-ANA-CHW Combo Test is a lateral flow immunochromatographic assay for the qualitative detection of Ehrlichia canis (EHR) antibodies, Leishmania (LSH) antibodies and Anaplasma spp (ANA) antibodies and Heartworm (CHW) antigens in dog's serum, plasma and whole blood specimen.
Assay Time:  5-10 minutes
 
Ehrlichia Leishmania Anaplasma Heartworm Combo Test
Product Name Canivet EHR-LSH-ANA-CHW Combo Test
Specimen serum, plasma and whole blood
Assay Time 5-10 minutes
Part No. VD084
MOQ 800 test kits
Delivery time 1 week after Get payment
Packing 10 test kits/Packing box
Storage Temperature 2-30°C,DO NOT FREEZE. Do not store the test kit in direct sunlight.
Shelf Life 18 months
Production Capacity 1 Million/Day
Payment T/T, Western Union, Paypal


Principle
The Canivet EHR-LSH-ANA-CHW Combo Test is based on sandwich lateral flow immunochromatographic assay. The test card has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into each sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated Ehrlichia, Leishmania, Anaplasma recombinant antigens and heartworm antibodies respectively. If there are Ehrlichia, Leishmania, Anaplasma antibodies or Heartworm antigens in the specimen, a visible T line will appear. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of Ehrlichia, Leishmania, Anaplasma antibodies and Heartworm antigens in the specimen.
Ehrlichia Leishmania Anaplasma Heartworm Combo Test
Ehrlichia Leishmania Anaplasma Heartworm Combo Test
 
CERTIFICATES
ISO9001&GMP
Ehrlichia Leishmania Anaplasma Heartworm Combo Test
Ehrlichia Leishmania Anaplasma Heartworm Combo Test


TEST PROCEDURE 
  • Take out the test card from the foil pouch and place it horizontally.
  • Use the capillary dropper to place 1 drop (approx.10μL) of the prepared specimen into each sample hole "S" of the test card. Then drop 3 drops (approx. 90μL) of the assay buffer into each sample hole. Start the timer.
  • Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.
Ehrlichia Leishmania Anaplasma Heartworm Combo Test


INTERPRETATION OF RESULTS
- Positive ():" C" line and "T" line exist simultaneously, whether the line is clear or blurred.
- negative(-): show clear C line. Only no T line.
- Invalid: No color line in C area. regardless of whether the T line appears or not.
 

Company Profile

Hangzhou Ever-Genetics Co., LTD. has a top colloidal gold product research and development team, strong technical strength, product quality ahead of similar products at home and abroad, after several times with the domestic and foreign well-known veterinary diagnostic reagents team cooperation, development and launch a series of broad market potential of livestock and poultry and pets with rapid diagnostic test paper products.
Adhering to the positive attitude and the concept of win-win, the company develops more and better products for the international veterinary rapid diagnosis field. We are willing to contribute our youth and wisdom to the agriculture and animal disease detection industry. We are willing to join hands with those who are interested in creating the spring of rapid diagnosis of animal diseases in China!
Ehrlichia Leishmania Anaplasma Heartworm Combo Test
Shipmemt
Ehrlichia Leishmania Anaplasma Heartworm Combo Test
Veterinary Tests we Supply

Ehrlichia Leishmania Anaplasma Heartworm Combo Test


FAQ

Q: Are you trading company or manufacturer?
A: We are professional manufacturer specialized in orthopedic and sport products. And we trade our products with our clients directly.

Q: Can you do OEM and ODM?
A: Yes, OEM and ODM are both acceptable. The material, color, style can customize, the basic quantity we will advise after we discuss.

Q: Can we use our own logo?
A: Yes, we can print your private logo according to your request.

Q: How many packaging do you have?
A: We have five packages including PE bag, hand bag, zip lock bag, colorful box and white box currently.

Q: Can you do our own packaging?
A: Yes, you just provide the package design and we will produce what you want. We also have the professional designer can help you do the packaging design.
 
Short Introduction

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier